Electrical Power Testing
Showing 49–96 of 832 results
- Electrical Power Testing
Datwyler 900um PLC Fibre Splitter
Product Specifications
Brand Datwyler Operating Temperature -40 to +85 deg C
Country of origin Uae
Applications FTTx Networks
Passive Optical Networks
Telecommunication Networks
LAN, WAN & Metro Networks
Measurement Wavelength 1260-1650 nm
Storage Temperature -40 to +85 deg C
SKU: n/a - Electrical Power Testing
Fluke 113 EUR Utility Multimeter
Key features
- integral Holster with Probe Holders for Easy Storage.
- Auto & Manual Ranging for Added User Functionality.
- The Optional Tpak Magnetic Hanger allows The User Hands-free Flexibility.
- A Large Backlit Display allows for Easy Visibility in Low-Lit Areas.
SKU: n/a - Electrical Power Testing
Fluke 115 Digital Multimeters
Product Specifications
Brand Fluke Battery Life 400 hr
Capacitance 1000 nF-9999 ?F
Continuity 600 ? – 40.00 M?
Diode Test 2.000 V
Display Count 6000
Humidity 0 % to 90 % to 35 deg C; 75 % to 40 deg C; 45 % to 50 deg C
Maximum Voltage 600 V RMS
Model 115
Operating Altitude 2000 m
Operating Temperature -10 deg C to 50 deg C
Protection IP42
Standard IEC 61010-1 Pollution Degree 2
IEC 61010-2-033 CAT III 600 V 10 A
EMC IEC 61326-1: Portable
Storage Temperature -40 deg C to 60 deg C
Voltage Range 600.0 mV-600.0 V DC & AC
SKU: n/a - Electrical Power Testing
Fluke 117 TRUE RMS Electrical Multimeter with Non-Contact Voltage
Key features
- Measures Resistance, Continuity, Frequency, & Capacitance.
- Provides Min/Max/Average to Record Signal Fluctuations.
- Comes with an Holster with Probe Holders for Easy Storage.
- Features Compact Ergonomic Design for One-Handed Operation.
SKU: n/a - Electrical Power Testing
Fluke 1503 Insulation Resistance Meter
Product Specifications
Brand Fluke Accuracy Measure: 500-1000 V
Test voltage: + 20% 0%
Battery Type AA
Current Short Circuit- 1 mA nominal
Dimension 5.0×10.0x20.3 cm
Humidity 0% to 95%
0% to 75%
0% to 40%
Maximum Voltage 600 V AC
Model 1503
Operating Altitude Operating: 2000 m
Non-operating: 12000 m
Operating Temperature -20 deg C to 55 deg C
Protection IP 40
Standard Complies with ANSI & ISA 82.02.01 (61010-1) 2004 CAN & CSA-C22.2 NO. 61010-1-04 & IEC & EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
Storage Temperature -40 deg C to 60 deg C
Test Voltage 500-1000 V
Weight 550 g
SKU: n/a - Electrical Power Testing
Fluke 1630-2 FC 1000V Earth Ground Clamp Meter
Key features
- Earth Ground AC Leakage Current Measurement.
- Heavy-Duty Clamp Jaw Stays in Alignment & in Calibration Even in Every Day, On-The-Job Industrial Environments.
- Identify AC Leakage Currents Without Disconnecting the Earth Ground Stake from the Grounding System.
SKU: n/a - Electrical Power Testing
Fluke 1662 UK Multifunction Tester with Phase Sequence
Key features
- A Solid, Reliable, Basic Installation Tester.
- Tests Voltage & Frequency.
- Checks Wiring Polarity to Detect Broken N Wires.
- Measures Insulation Resistance & Loop & Line Resistance.
- Measures Motor Windings with Continuity Test.
- Calculates Prospective Earth Fault Current (PEFC/IK) & Prospective Short-Circuit Current (PSC/IK).
SKU: n/a - Electrical Power Testing
Fluke 1AC Voltalert
Product Specifications
Brand Fluke Battery Type 2 AAA
Humidity 0 % to 95 % (0 deg C to 30 deg C)
0 % to 75 % (30 deg C to 40 deg C)
0 % to 45 % (40 deg C to 55 deg C)
Model 1AC
Operating Altitude 3000 m
Operating Temperature -10 deg C to +50 deg C
Protection IP 40
Safety Rating 1000 V CAT IV
Voltage Range 90-1000 V AC
SKU: n/a - Electrical Power Testing
Fluke 27II/EUR Rugged Digital Multimeter
Product Specifications
Brand Fluke AC Current Accuracy 1.5% + 2
AC Voltage Range: 0.1 mV to 1000 V
AC Voltage Accuracy 0.5% + 3
Battery Life 800 hr
Capacitance 1 nF to 9999 ?F
Current DC: 0.1 ?A to 10 Amp
AC: 0.1 ?A to 10 Amp
DC Current Accuracy 0.2% + 4
DC Voltage Range: 0.1 mV to 1000 V
DC Voltage Accuracy 0.1% + 1
Dimension 6.35×10.0x19.81 cm
Display Count 6000
Frequency 0.5 Hz to 199.99 kHz
Model 27II/EUR
Protection IP 67
Weight 698.5 g
SKU: n/a - Electrical Power Testing
Fluke 287/EUR TRUE RMS Electronics Logging Multimeter with Trendcapture
Product Specifications
Brand Fluke Battery Life 100 hr
Battery Type 6 AA
Capacitance Range & Resolution: 1.000 nF10.00 nF 100.0 nF 1.000 ?F 10.00 ?F 100.0 ?F 1000 ?F 10.00 mF 100 mF
Current Range & Resolution: 500.00 ?A 5000.0 ?A 50.000 mA 400.00 mA 5.0000 Amp 10.000 Amp DC & AC
Dimension 22.2×10.2×6 cm
Frequency Range & Resolution: 99.999 Hz 999.99 Hz 9.9999 kHz 99.999 kHz 999.99 kHz
Humidity 0 to 90 % (0 t 37 deg C) 0 to 65 % (37 deg C to 45 deg C) 0 to 45 % (45 deg C to 55 deg C)
Maximum Voltage 1000 V
Model 287/EUR
Operating Temperature -20 deg C to 55 deg C
Resistance Range: 500.00? 5.0000 k? 50.000 k? 500.00 k? 5.0000M? 50.00M? 500.0M?
Standard IEC 61010-1 Pollution degree 2
IEC 61010-2-033: CAT IV 600 V CAT III 1000 V
Storage Temperature 40 deg C to 60 deg C
Temperature Range & Resolution:200.0 deg C to 1350.0 deg C
Voltage Range Range & Resolution: 50.000 mV500.00 mV 5.0000 V 50.000 V500.00 V 1000.0 V AC & DC
Weight 870.9 g
SKU: n/a - Electrical Power Testing
Fluke 289/EUR TRMS Industrial Logging Multimeter with Trendcapture
Product Specifications
Brand Fluke AC Current Accuracy 0.60%
AC Voltage Accuracy 0.40%
Battery Life 100 hr
Battery Type 6 AA
Capacitance Range & resolution: 1.000 nF10.00 nF 100.0 nF 1.000 ?F 10.00 ?F 100.0 ?F 1000 ?F 10.00 mF100 mF
Current Range & Resolution: 500.00 ?A 5000.0 ?A 50.000 mA400.00 mA 5.0000 Amp 10.000 Amp DC & AC
DC Current Accuracy 0.05%
DC Voltage Accuracy 0.025%
Dimension 22.2×10.2×6 cm
Frequency Range & Resolution: 99.999 Hz 999.99 Hz 9.9999 kHz99.999 Hz 999.99 Hz 9.9999 kHz
Humidity 0 to 90 % (0 t 37 deg C) 0 to 65 % (37 deg C to 45 deg C) 0 to 45 % (45 deg C to 55 deg C)
Maximum Voltage 1000 V
Model 289/EUR
Operating Temperature -20 deg C to 55 deg C
Storage Temperature 40 deg C to 60 deg C
Temperature Accuracy Range & Resolution:200.0 deg C to 1350.0 deg C
Voltage Range Range & Resolution: 50.000 mV 500.00 mV 5.0000 V50.000 V 500.00 V 1000.0 VDC & AC
Weight 870.9 g
SKU: n/a - Electrical Power Testing
Fluke 2AC Non Contact Voltage Tester
Product Specifications
Brand Fluke Altitude 200 m
Battery Life 1 year
Humidity 0% to 95%
0% to 75%
0% to 45%
Model 2AC
Operating Temperature -10 deg C to 50 deg C
Standard IEC 61010-1:2001
UL 61010-1
CAN & CSA-C22.2 No. 61010-1-04
ISA-82.02.01 Pollution Degree 2
Meets IEC 61326-1:2006
Voltage 90-1000 V AC
CAT IV: 1000 V
SKU: n/a