Schneider
Showing 337–384 of 4006 results
- Hydraulics and Pneumatics, Pneumatic Tools
Schneider 12A 250 VAC RXM2 Screw Connector Timer Relay, RXZE2S108M
Hydraulics and Pneumatics, Pneumatic ToolsSchneider 12A 250 VAC RXM2 Screw Connector Timer Relay, RXZE2S108M
Product Specifications
Brand Schneider Ambient Temperature Storage (Air): -40 to 85 deg C
Operation (Air): -40 to 55 deg C
Certification Ul, Csa & Lloyd’S
Compatibility Plug-In Relay Rxm with 2 C/O ContACt
Plug-In Relay Rexl with 2 C/O ContACt
Connections Terminals: Connector, 2X0.5-2X1.5 mmâ² (Awg 20-Awg 16) Solid without Cable End
Connector, 1X0.25-1X2.5 mmâ² (Awg 22-Awg 17) Flexible with Cable End
Connector, 1X0.5-1X2.5 mmâ² (Awg 22-Awg 14) Flexible with Cable End
Connector, 2X0.25-2X1 mmâ² (Awg 20-Awg 14) Solid without Cable End
Current Conventional Free Air Thermal: 5 Amp with Bus Jumper
12 A
Dielectric Strength 2500 V
Fixing Mode By Screw (Panel)
ClIP-on (35 mm Symmetrical Din Rail)
Item Code RXZE2S108M
Operating Voltage Rated: < 250 V
Pins Flat
Protection Class IP20 Conforming to En/Iec 60529
Range Zelio Relay
Serial interface Zelio
Shape Pin: Flat
Standards IEC 61984
Storage Temperature Air: -40 to 85 deg C (Ambient)
Torque Tightening : <1 N.M For M3 Screw(S)
Type Rxm2
Voltage Rated Operational: <250 V
Weight 0.058 Kg
Width 27 mm
SKU: n/a - Electrical Power Testing
Schneider 12A 3 Circuits Body for Ammeter Switch, K1F003M
Product Specifications
Brand Schneider Ambient Temperature Operation: ‘-25 to 55 deg C
Storage: -40 to 70 deg C
Current Air Thermal Current: 12 Amp
Diameter Fixing Mode: 22 mm hole
Electrical Durability 1000000cycles AC-15
1000000 cycles AC-21
500000 cycles AC-23
500000 cycles AC-3
Impulse Withstand Voltage 4 kV in Isolating Function
6 kV Conforming to IEC 947-1
Item Code K1F003M
Material Plastic
Measurement 3 Circuits
Operational Current 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3
2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3
2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3
3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3
3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3
4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3
4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3
5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3
1 A at 500 V AC-15 conforming to IEC 947-5-1
2 A at 400 V AC-15 conforming to IEC 947-5-1
3 A at 230 V AC-15 conforming to IEC 947-5-1
Power 10500 W AC-21, 550…600 V 3 phases conforming to IEC 947-3
1100 W AC-3, 230 V 3 phases conforming to IEC 947-3
1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3
1500 W AC-3, 400 V 1 phase conforming to IEC 947-3
1500 W AC-3, 400 V 3 phases conforming to IEC 947-3
1500 W AC-3, 500 V 3 phases conforming to IEC 947-3
1500 W AC-3, 690 V 3 phases conforming to IEC 947-3
2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3
2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3
2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3
4800 W AC-21, 230 V 3 phases conforming to IEC 947-3
600 W AC-3, 230 V 1 phase conforming to IEC 947-3
8300 W AC-21, 400 V 3 phases conforming to IEC 947-3
Rated Insulation Voltage 690 V (pollution degree 3) conforming to IEC 60947-1
Short Circuit Current 10000 Amp
Standards EN/IEC 60947-3 for power Circuit
EN/IEC 60947-5-1 for Control Circuit
Cenelec EN 50013
Suitable For Ammeter Switch
Switching Positions: Right: 0 deg-90 deg-180 deg -270 deg
Switching Angle 90 deg
short circuit protection 16 A Cartridge Fuse, Type gG
SKU: n/a